Similar presentations:
6-Presentazione tecnica PHASYS (inglese)
1. PHASYS
TRAINING COURSETLC INVERTER
PHASYS
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
1
2. VERSIONS AVAILABLE
PHASYS 1500PHASYS 3000
PHASYS 4500
PHASYS 1500 plug-in
PHASYS 3000 plug-in
PHASYS 4500 plug-in
PHASYS STAR
PHASYS ELITE
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
2
3. PHASYS 1500
Inverter Module 1500VAVersion “stand alone” rack 19” and plug-in
Input Voltage range between 39V and 58V
Nominal output Voltage 208/220/230/240 Vac
With 208V Output configuration, output Power
derating is 80%
Motherboard PCB for all inverter series
(Output LEM configuration by dip-switch
setting)
N.1 Power PCB used
Output Power derating above 40°C
(environment temperature)
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
3
4. PHASYS 3000
Inverter Module 3000VAVersion “stand alone” rack 19” and plug-in
Input Voltage range between 39V and 58V
Nominal output Voltage 208/220/230/240 Vac
With 208V Output configuration, output Power
derating is 80%
Motherboard PCB for all inverter series (Output
LEM configuration by dip-switch setting)
N.2 Power PCBs used
Output Power derating above 40°C
(environment temperature)
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
4
5. PHASYS 4500
Inverter Module 4500VAVersion “stand alone” rack 19” and plug-in
Input Voltage range between 39V and 58V
Nominal output Voltage 208/220/230/240 Vac
With 208V Output configuration, output Power
derating is 80%
Motherboard PCB for all inverter series (Output
LEM configuration by dip-switch setting)
N.3 Power PCBs used
Output Power derating above 40°C
(environment temperature)
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
5
6. PHASYS STAR
The Intelligent Communication Modulecollects and elaborates data from the
individual modules and renders this
information available to the user via the
System display.
Connected to the controller PCB, there is a
synoptic PCB (this is formed by backlighting
L.C.D. (16x2 characters), two buttons and
four LEDs.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
6
7. PHASYS ELITE H1400
Power Supply with rack 19” Cadrys cabinet (low orhigh power)
3000VA with 2+1 1500VA
3000VA with 1+1 3000VA
Low Power
4500VA with 3+1 1500VA
6000VA with 2+1 3000VA
9000VA with 3+1 3000VA
9000VA with 2+1 4500VA
13500VA with 3+1 4500VA
High Power
18000VA with 4 x 4500VA
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
7
8. PHASYS ELITE H1800
Power Supply with rack 19” Cadrys cabinet (low orhigh power)
3000VA with 2+1 1500VA
3000VA with 1+1 3000VA
4500VA with 3+1 1500VA
Low Power
6000VA with 2+1 3000VA
9000VA with 3+1 3000VA
9000VA with 2+1 4500VA
13500VA with 3+1 4500VA
High Power
18000VA with 4 x 4500VA
The options (transformer or batteries) may be installed
in the compartment located underneath the inverters.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
8
9. Inverter PHASYS - internal view
Power PCBRegulation PCB
Motherboard
PCB
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
9
10. Inverter main features
Environment temperature range between 0 a 55°C.Output nominal voltage configurations are 208/220/230/240Vac
Reinjected psophometric noise 2mV psoph.
Reinjected RMS ripple 100mV.
Output Power derating with 208V setting.
Integrated Static By-pass.
Permanent overload 105%.
almost all wireless and
plug-in version (hot-swap).
output power derating above 40°C
(approx. -30W/°C).
Forced ventilation and fan speed is
depended on the output power.
advanced control of the ventilation
(the regulation PCB calculates the real
rotation speed of each fan).
All inverters operate in parallel in load sharing mode by can bus and
ensure that any faulty module is disabled by means of selective
disconnection.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
10
11. Mother-board PCB
Only Board for all the serie (anotherversion for “stand alone” module)
“Active” input filter
Hot-plug: input capacitors pre-charge and
protection against the reversal
Output EMI filter
Isolated measure of input voltage
Protection against the reversal of the input
polarity (optional); this device is standard
on “stand alone” module version.
Serial Port RS232 with DB9 connector (on
the back of inverter)
availability of 1+1(optional) dry contact
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
11
12. Power PCB
Power PCB 1500VAAssembly lacking in connections (wireless)
Same board MODULYS and PHASYS (distinguished
bars of assembly)
Isolated Drivers in the DC/DC converter
“Active Clamper” when the inverter works above 53V
of voltage battery.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
12
13. Regulation Inverter PCB
Only board for all module rangeAssembly lacking in connections (wireless)
Same board MODULYS and PHASYS
(distinguished bars of assembly)
Digital control them on all the functions
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
13
14. Power Supply
The System is designed observing modularity criteria(controller PCB plug-in).
Output Power between 3kVA and 18kVA.
Maximum 4 inverter modules in parallel (only the same
module power).
Integrated Auxiliary Distribution AC (optional)
Advanced Communication and supervision systems
(Net Vision).
Cured design.
Versatile options in the System (predisposition with
minimum arrangements).
Options: Input mains transformer, manual By-pass,
back feed protection, second battery fuse,
batteries/rectifiers compartment.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
14
15. Controller PCB
Controller PCB is hot swap and plug in (the board isplaced on a flowing tray; its maintenance and
substitution is of simple execution).
Remote supervision via LAN through Net Vision and
RS232 serial.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
15
16. Interface System and Dry contacts PCB
SIGNALS AVAILABLEGeneral alarm
Load on By-pass
Auxiliary mains voltage absent or out
of tolerance
Pre-minimun battery alarm
Compatibility between SHARYS and
PHASYS
The maximum voltage that can be
applied to these contacts is 250Vac, the
maximum current is 5A.
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
16
17. SUPERVISION SYSTEM
NET VISIONREMOTE
SUPERVISION
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
17
18. SUPERVISION SYSTEM
NET VISIONREMOTE
SUPERVISION
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
18
19. Personal notes
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/200219
20.
THANKSFOR YOUR
ATTENTION
NEW INVERTER PHASYS TLC PRESENTATION - 04/12/2002
20