How to Use Color-Navi
Color-Navi (Metallic-CCM for BAROMATCH)
8.53M
Category: informaticsinformatics

How to Use Color-Navi

1. How to Use Color-Navi

Metallic-CCM

2. Color-Navi (Metallic-CCM for BAROMATCH)

2

3.

Contents
Set up & Preparation
Making Formula using Color-Navi
Color DB
Question
3

4.

1. Set up
1
Components
Computer
Semi-Booth
(for Trial pannels)
• CPU : Core2 Duo
2.4Ghz
• RAM : 4GB
• HDD : 100GB
Color-Navi
• CCM Software
• Careful of virus
Spectrophotometer
• AA Battery (4ea)
• USB Connection Cable
4
Baromatch

5.

2. How to use CCM (Metallic)
Power On
1
① Power-ON
Computer
On
② Measuring Body
③ Searching
④ Selection Candidate
Connecting
Spectrophotometer
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
Run Program
(Color-Navi)
⑧ Storing Pannel
5

6.

2. How to use CCM (Metallic)
2
Measuring Body
① Power-ON
② Measuring Body
Calibration
: every 1month
③ Searching
④ Selection Candidate
Body Measure
(cleaning Target → Measure)
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
Measured Data Load
⑧ Storing Pannel
6

7.

2. How to use CCM (Metallic)
3
Searching
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
⑧ Storing Pannel
7

8.

2. How to use CCM (Metallic)
4
Selection Candidate
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
Tip :
① Considerinig about
Sparkling, the KCC code
can be helpful.
⑥ Correction
⑦ Make Trial Pannel
② Also, it can be a good
choice that has similar
shape of R-Curve.
⑧ Storing Pannel
8

9.

2. How to use CCM (Metallic)
5
Check how different
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
⑧ Storing Pannel
9

10.

2. How to use CCM (Metallic)
6
Auto-correction /
Manual Simulation
① Move to next step.
(Now you are C1, after
click here, then you’ll be C2)
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
② After move next step,
⑧ Storing Pannel
please click here, then
you can get a corrected
formula.
10

11.

2. How to use CCM (Metallic)
6
Auto-Correction
/ Manual Simulation
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
Tip :
① You can make manual
formula which has smaller
dE at specific degree.
⑥ Correction
⑦ Make Trial Pannel
⑧ Storing Pannel
② You can also make
formula which will be
close to actual viewing,
even though that formula
drive to bigger dE.
11

12.

2. How to use CCM (Metallic)
7
Make Trial Pannel
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
⑧ Storing Pannel
12

13.

2. How to use CCM (Metallic)
8
Storing Pannel
① Power-ON
② Measuring Body
③ Searching
④ Selection Candidate
⑤ Check Color difference
⑥ Correction
⑦ Make Trial Pannel
⑧ Storing Pannel
13

14.

* CIE_Lab
CIELab UCS
(Uniform Color Space)
b*
L*
Lightness
b*
Chroma
a*
a*
14

15.

* CIE_Lab
+ 100 b*
- 100 a*
100 L*
a*
C*
h
b*
+ 100 a*
L*
0 L*
- 100 b*
Illum
BARN RED 4X D65
L*
a*
30.86
44.04
15
b*
18.50

16.

* CIE_Lab
Target
Trial
L* = 30.86
a* = 44.04
b* = 18.50
L* = 32.91
a* = 46.66
b* = 19.54
16
=
Trial is ..
Lighter
Redder
More Yellowish
DL* = 2.05
Da* = 2.62
Db* = 1.04

17.

* CIE_Lab
CIELab
+DL*
Lighter
- DL*Darker
+Da*
Redder (or) less Green
- Da*more Greenish (or) less Red
+Db*
more Yellowish (or) less Blue
- Db*
more Bluish (or) less Yellow
E
*
ab
( L )
* 2
* 2 12
( a ) ( b )
* 2
17