System Implementation Proposal
Requirements summary & motivation
Functions proposed to be removed
Functions proposed to be removed
Functions proposed to be removed
Functions proposed to be removed
1.13M

SYS SIP - Removal of obsolete functionality for REVIEW IL

1. System Implementation Proposal

PSNM-SAP 2013-01-10
System Implementation Proposal
SYS 600 – Removal of obsolete functionality
© ABB
Month DD, YYYY | Slide 1

2. Requirements summary & motivation

Requirements summary & motivation
Summary
© ABB
Month DD, YYYY | Slide 2
Remove obsolete functionality from SYS 600
Motivation
To ease maintenance
To ease migration to new Development Environment
To recycle attribute names
Most of obsolete functionality has already been
undocumented for years

3. Functions proposed to be removed

MicroTerminal support and IND base system objects
Not supported anymore
Not use
DCP/MUX support (incl. RAM_PROTOCOL)
Not supported anymore
Not use
PICL (Semigraphic picture documenter module)
Not applicable anymore
Not use
Picture cache for semigraphic pictures (incl. SYS attributes PC and PU)
These pictures are not used much anymore and the display handling do not need to
be optimized nowadays
Not use
SYS attributes
HM (Hansi Motif)
MM (Memory Map)
EP, ED, TP, TD (Excom Communication)
FM, FU (Open file counts)
Not use
© ABB
Month DD, YYYY | Slide 3

4. Functions proposed to be removed

APL attributes
ON (Override Native)
Not use
MON attributes
EX (Executive)
ON (Override Native)
ND, TN, DC, MA, IA, CA (obsolete monitor types)
Not use
LIN attributes
MA, IA (DCP/MUX)
BR, SB, PY, FC, ER, EN, RE, SD (obsolete kernel protocols)
Not use
SCIL language features
#SET_SYSPAR command
SYSPAR function
Not use
© ABB
Month DD, YYYY | Slide 4

5. Functions proposed to be removed

SPACOM SCIL function and SYS attributes SP and
SD
This applies to direct communication between the
kernel and a SPA device (using a serial port of the
SYS computer)
Not use
Support for external clocks PC32 and Meinberg
Not use
Support for audio alarm cards Nudaq and Advantech
Not use
Process object type FT (File Transfer) earlier used
for uploading Disturbance Record files
Not use
© ABB
Month DD, YYYY | Slide 5

6. Functions proposed to be removed

History logging policy ”EVENT_LOG” and APL attributes HP and
HB
This is the old text based storage of events, used by LIB 4.0.1
and older
Use only one old project
Aliasing of APL and STA base system objects
Aliasing is done by setting the TT (Translation Type) attribute
value to ”ALIAS”
As an example, if APL6:BTT = ”ALIAS” and APL6:BTN = 5,
application 5 may be referred to by using application number 5
or 6 in SCIL.
Not use
SCILC.EXE
Command line execution of SCIL
We use scilc.exe: for run our install scripts for our tools, for run
SCIL-patches on site MicroSCADA.
© ABB
Month DD, YYYY | Slide 6
English     Русский Rules