CFD Analysis Report for Will Towers in Russia

1.

CFD Analysis Report
Will Towers in Russia
• Analysis : Outdoor airflow
• Vertical : Residential
• Product : Multi V 5
2020.01
LG Electronics / CAC Engineering Sil

2.

Legal Disclaimer
CAC Engineering Division of LG Electronics does not make any warranty, express or
implied, nor assumes any legal liability or responsibility for the accuracy,
completeness, or usefulness of any information, apparatus, product, or process
disclosed, nor represents that its use would not infringe privately owned rights. The
models described in this report are intended to demonstrate the potential thermal and
air flow patterns of possible energy improvements for the new facilities. Due to the
limitation of the Computational Dynamics Analysis including differences of physical
models and the real world, boundary conditions, and numerical errors, the
conclusions of this report do not guarantee actual thermal and air flow profiles or
system performances.
※ This CFD analysis is the result without considering certain environment condition, thus there can be a difference with the actual operation.

3.

Project Overview
1. Purpose
-. Review the normal operation and improvement through CFD analysis
2. PJT : Will Towers in Russia
3. Product type : MULTI V 5 (ARUM120LTE x 82EA, UXA chassis)
4. Analysis program
-. Pre-Process : ANSYS Fluent V19.2
-. Analysis & Post Process : ANSYS Fluent V19.2
Drawing
-. Viscous model : Realizable k-ε
5. Boundary conditions
-. Ambient temp. : 35 ℃
-. Operating ratio : 100%
-. Flat louver, Opening ratio 95% (pitch 200mm, thickness 10mm, 0 degree)
-. Issues : 41 floors building, 2 ODUs on the technical balcony of each stage
Installation of the air guide
6. Analysis cases
-. Case1. CAD Drawing
Modeling
※ This CFD analysis is the result without considering certain environment condition, thus there can be a difference with the actual operation.

4.

CAD drawing (Plan views)
-. Issues : 41 floors building, 2 ODUs on the technical balcony of each stage
Installation of the air guide
※ This CFD analysis is the result without considering certain environment condition, thus there can be a difference with the actual operation.

5.

CAD drawing (Side view)
-. Issues : 41 floors building, 2 ODUs on the technical balcony of each stage
Installation of the air guide
※ This CFD analysis is the result without considering certain environment condition, thus there can be a difference with the actual operation.

6.

3D Modeling
-. Dimensions : see site drawings
Top view
ISO view
Side view
Front view
※ This CFD analysis is the result without considering certain environment condition, thus there can be a difference with the actual operation.

7.

Results
-. Case. CAD Drawing
-. Max inlet air temp. of heat exchanger is 40.5 ℃. (Continuous operation temp. 48 ℃)
It would be in operation range
Pathline & Contour
Static
temperature
(°C)
Pathlines (Side view)
CC’ section
Inlet air temp. of heat
exchanger (41 floor)
AA’ section
BB’ section
Zoom on AA’ section
※ This CFD analysis is the result without considering certain environment condition, thus there can be a difference with the actual operation.