Training screw compressors
Package designation code
Package designation code
Package designation code
P+I diagram – designation code
LARGE – Piping diagram old
LARGE – Piping diagram NEW
LARGE – Package
LARGE – oil return
MEDIUM – Piping diagram
MEDIUM – components of Package
Optional equipment I
Optional equipment II
SMALL – Piping diagram
SMALL – components of Package
SMALL - package
SMALL - package
Option - Liquid injection
DUO Pack
DUO Pack - solenoid valve block
LT-DUO–external oil pump
LT-DUO–external oil pump–new design
MC-DUO–Internal– P+I - old
MC-DUO–Internal–MD11
MC-DUO–Internal–P+I - new
MC-DUO–Internal–MD11-R1
MC-DUO–external–p+I -old
MC-DUO–external–MD12
MC-DUO–external–P+I - new
MC-DUO–external–MD12-R1
SH-DUO–internal–P+I -new
SH-DUO–internal–SD11-R1
SH-SD11-R1-photo
SH-DUO–external–P+I - new
SH-DUO–external–SD12-R1
LT-DUO- start control
LT-DUO-start control mod.
DUO-internal oil pump-start control
Chillers – FX PP
Chillers – FX PP
Chillers – FX VP
Chillers – FX VP
Chiller – FX VP
FX VP- Injector
FX VP- drainer
Chiller DX RR
Chiller DX LR
Oil separator / MEDIUM & LARGE
Oil separator / LARGE
Oil separator / LARGE
Oil separator SMALL
Level switches
Oil cooler: HS COOLER
Oil cooler: HS COOLER
Oil cooler: HS COOLER
Oil cooler: AEL
Oil cooler: AEL
Suction filter
Steel lamination coupling
Steel lamination coupling
Steel lamination coupling
Coupling SMALL
Option –oil filter P+I
Option – double oil filter
Temperature sensor
Fine filter cartridges
Oil heater
Oil heater I
Oil heater II
Motorbefestigung - fixator
Multifunctional block I
Multifunctional block II
Multifunctional block III
Multifunctional block IV
Multifunctional block V
Multifunctional block VI
Multifunctional block VII
3-way valve
Oil pressure regulating valve
Oil pump
Oil pump II
Pressure sensor
15.80M
Category: industryindustry

Training screw compressors

1. Training screw compressors

Grasso
Training screw compressors
Geschäftsbereich
Kältetechnik
Grasso GmbH Berlin
Service Department
Schulung / Training
PART II
Schraubenverdichteraggregate & Komponenten
screw compressors packages & components
28.10.2002
Service Department (ESS)
1

2. Package designation code

Grasso
Package designation code
Geschäftsbereich
Kältetechnik
Bezeichnung / Designation code
Bezeichnung / Designation code
X
Y - 9
A
(X1)
Typ Verdichter / Compressor type
Ausführung Aggregat / Design compressor package
Ausführung Verdichter / Design compressor
Ölabscheidung, -kühlung / Oil separation, oil cooling
Baugröße (2-stufig) HD/ Compressor type 2-stage HP
28.10.2002
Service Department (ESS)
2

3. Package designation code

Grasso
Package designation code
Geschäftsbereich
Kältetechnik
Aggregatebezeichnung / Package designation code
X
SCHRAUBENVERDICHTERTYP / SCREW COMPRESSOR TYPE
C, D, E, G, H, L, M, N, P, R, S, V,W, Y, Z, XA, XB, XC, XD, XE, XF
Y
Aggregateausführung / design screw compressor package
Codeletter
NH3
R22
HFKW
R290 /
R600a
CO2
Oil separator - horizontal - base / Ölabscheider – horizontal- unter
A
H
R
F
O
Oil separator - vertical/ Ölabscheider – vertikal
B
K
S
G
P
Oil separator horizontal in row/Ölabscheider horizontal - in Reihe
C
L
T
Duo-Pack
D
M
V
Two stage packages / Zweistufige Aggregate
E
N
U
28.10.2002
Service Department (ESS)
3

4. Package designation code

Grasso
Package designation code
Geschäftsbereich
Kältetechnik
Ausführungsvariante/Design type:
9
A
Codeletter
Merkmale
Features
Vi
1
Vi fest
Vi fixed
2.6
2
Vi fest
Vi fixed
3.6
3
Vi fest
Vi fixed
4.8
4
Vi fest
Vi fixed
5.5
5
Vi variabel
Vi variable
2.6-4.8; 2.6-4.0; 3.2-4.8
6
Booster, Vi dest
Booster, Vi fixed
2.6; 3.6
7
Wärmepumpe
Heat pump
2.6; 3.6
8
SMALL – 2 Leistungstufen
SMALL- 2 capacity steps
2.6; 3.6; 4.8
9
Freqwuenzgesteurert,Type G, N
Frequency controlled, TypeG, N
Stufenlos/Continuously.
ÖLABSCHEIDUNG, ÖLKÜHLUNG / OIL SEPARATION - OIL COOLING
code
letter
A
B
C
D
E
F
28.10.2002
Mit Feinölabscheidung
With oil fine separation
Wassergekühlte Ölkühler,
Water cooled oil cooler
Kältemittelgekühlte Ölkühler,
Refrigerant cooled oil cooler
Kältemitteleinspritzung,
Refrigerant injection
Wasser- und kältemittelgekühlte Ölkühler
Water and refrigerant cooled oil cooler
Wasser- oder kältemittelgekühlte Ölkühler in
Verbindung mit Kältemitteleinspritzung,
Water or refrigerant cooled oil cooler and
refrigerant injection
Ohne Ölkühler , Without oil cooler
code
letter
G
H
K
L
M
N
Ohne Feinölabscheidung
Without oil fine separation
Wassergekühlte Ölkühler,
Water cooled oil cooler
Kältemittelgekühlte Ölkühler,
Refrigerant cooled oil cooler
Kältemitteleinspritzung,
Refrigerant injection
Wasser- und kältemittelgekühlte Ölkühler
Water and refrigerant cooled oil cooler
Wasser- oder kältemittelgekühlte Ölkühler in
Verbindung mit Kältemitteleinspritzung,
Water or refrigerant cooled oil cooler and refrigerant
injection
Ohne Ölkühler , Without oil cooler
Service Department (ESS)
4

5. P+I diagram – designation code

Grasso
P+I diagram – designation code
Geschäftsbereich
Kältetechnik
R+I Schema – Bezeichnung / P+I diagram-designation code
1. Buchstabe
Meßgröße
Druck
Temperatur
Niveau
Current
Durchfluß
Position
P
T
L
E
F
G
1st indication letter
measurand
Pressure
Temperature
Level
Current
Flow
Position
D
Zusatz zur Meßgröße
Differenz
Add on for measurand
Differential
I
S
A
C
T
Z
Folgebuchstabe
Funktion
Anzeige
Schaltung
Alarm
Steuerung
Meßumformer-Fktn.
Schutzeinrichtung
following indication letter
Function
Indication
switch
Alarm
Control
Transformer-Fctn.
Protection device
28.10.2002
Service Department (ESS)
Bedienung und Anzeige am Gerät
Non-remote display control
Fernanzeigend
Remote display & control
5

6. LARGE – Piping diagram old

Grasso
LARGE – Piping diagram old
Geschäftsbereich
Kältetechnik
R+I Schema / P+I diagram
28.10.2002
Service Department (ESS)
6

7. LARGE – Piping diagram NEW

Grasso
LARGE – Piping diagram NEW
Geschäftsbereich
Kältetechnik
R+I Schema (neu) / P+I diagram (new)
28.10.2002
Service Department (ESS)
7

8. LARGE – Package

Grasso
LARGE – Package
Geschäftsbereich
Kältetechnik
LARGE Verdichteraggregat / LARGE Package
28.10.2002
Service Department (ESS)
8

9. LARGE – oil return

Grasso
LARGE – oil return
Geschäftsbereich
Kältetechnik
LARGE Ölrückführung / LARGE oil return
Filter, ID: 0726370
Blende/orifice 1.0mm - ID:0726330 (for 12mm piping / oil separator dm508)
Blende/orifice 1.6mm - ID:0726340 (for 12mm piping / oil separator dm711)
Blende/orifice 2.0mm - ID:0726350 (for 12mm piping / oil separator dm813)
Blende/orifice 2.4mm - ID:0726360 (for 12mm piping / oil separator dm1016)
28.10.2002
Service Department (ESS)
9

10. MEDIUM – Piping diagram

Grasso
MEDIUM – Piping diagram
Geschäftsbereich
Kältetechnik
R+I Schema / P+I diagram
28.10.2002
Service Department (ESS)
10

11. MEDIUM – components of Package

Grasso
MEDIUM – components of Package
Geschäftsbereich
Kältetechnik
010 Verdichter / screw compressor
055 Rückschlagventil (integriert) / check valve suction side (integrated)
015 Motor / compressor drive motor
060 Rückschlagventil / check valve - discharge side
020 Ölabscheider / oil separator
095 Kupplung / coupling
025 Filter mit Multifunktionsblock / oil filter with
multi-function block
180 Steuerung / compressor control device
030 Ölkühler / oil cooler
safety devices
040 Ölpumpe (integriert) / oil pump (integrated
into the compressor)
common base frame for all components
045 Saugfilter (integriert)/ suction filter
(intergated into the compressor)
28.10.2002
Service Department (ESS)
11

12. Optional equipment I

Grasso
Optional equipment I
Geschäftsbereich
Kältetechnik
Refrigerant Inlet - Type B
Kältemitteleintritt – Typ B
Official certification by TÜV (Germany)
TÜV Abnahme
Refrigerant Inlet - Type C
Kältemitteleintritt – Typ C
has to
connect with
suction line
Refrigerant Outlet - Type B
Kältemittelaustritt – Typ B
Refrigerant Outlet - Type C
Kältemittelaustritt – Typ C
DOPPELÖLFILTER/ EASY CHANGE OIL FILTER
Zur Injektion
injection cooling oil
Schmieröl
lubrication
vom Ölkühler
from oil cooler
oil separator
28.10.2002
Service Department (ESS)
12

13. Optional equipment II

Grasso
Optional equipment II
Geschäftsbereich
Kältetechnik
Kältemittel-gekühlte Ölkühler / Refrigerant cooled oil cooler
oil
oil Öl
to the
condenser
zum
Kondensator
Öl
to the
condenser
zum
Konden sa tor
ECONOMIZER ANSCHLUß / ECONOMIZER OPERATION
*
*
*
Flüssiges
Kältemittel
oil drain
liquid
refrigerant
Ölablaß
oil drain
F
oil flüssiges
Kältemittel
Öl oil
liquid refrigerant
Wärmerückgewinnung / Heat recovery
Kühlwasserregler / Thermostatic water valves
oil
Öl
cooling water
ports
to the
condenser
from oil separator
vom
Ölab scheid er
cooling
water
flüssiges
Kältemittel
zum
Konden sa tor
liquid
refrigerant
oil drain
28.10.2002
Öl
oil
zum
Verdichter
to the compressor
Service Department (ESS)
13

14. SMALL – Piping diagram

Grasso
SMALL – Piping diagram
Geschäftsbereich
Kältetechnik
R+I Schema /
P+I diagram
28.10.2002
Service Department (ESS)
14

15. SMALL – components of Package

Grasso
SMALL – components of Package
Geschäftsbereich
Kältetechnik
011 solenoid valve block
Magnetventilblock
045
suction filter (integrated) Saugfilter
(integriert)
012 position transducer
Wegsensor
055
check valve (integrated)
Rückschlagventil
(integriert)
015 compressor motor
Antriebsmotor
060
check valve
Rückschlagventil
020 oil separator
Ölabscheider
080
control valve (integrated) Regelventil Injektion
(integriert)
030 oil cooler
Ölkühler
095
Coupling
Kupplung
180
control device
Steuerung
035 oil filter (integrated) Ölfilter (integriert)
28.10.2002
Service Department (ESS)
15

16. SMALL - package

Grasso
SMALL - package
Geschäftsbereich
Kältetechnik
SMALL Verdichteraggregat / SMALL Package
28.10.2002
Service Department (ESS)
16

17. SMALL - package

Grasso
SMALL - package
Geschäftsbereich
Kältetechnik
SMALL Verdichteraggregat / SMALL Package
28.10.2002
Service Department (ESS)
17

18. Option - Liquid injection

Grasso
Option - Liquid injection
Geschäftsbereich
Kältetechnik
Kältemitteleinspritzung / Liquid injection
POS 550:
Eckventil / angle valve
POS 555:
Druckregulierventil
pressure regulating valve
POS 560:
Nadelventil / needle valve
POS 225:
Thermostatisches Expansionsventil
thermostatic expansion valve
28.10.2002
Service Department (ESS)
18

19. DUO Pack

Grasso
DUO Pack
Geschäftsbereich
Kältetechnik
Änderung Ölkreisläufe für Duo-Pack
Change of oil circuits for DUO-Packs
Ziel / goal:
•Vereinheitlichung / Gleiches Steuerungskonzept
•Unification / one control concept
Einführung: 09/2001
Introduction: 09 / 2001
28.10.2002
Service Department (ESS)
19

20. DUO Pack - solenoid valve block

Grasso
DUO Pack - solenoid valve block
Geschäftsbereich
Kältetechnik
Magnetventilblock für Duo-Pack
Solenoid valve block for DUO-Packs
Druckbegrenzungsventil
7 bar im Ventilblock
Überströmblende im Ventilblock
S5
Y1
Verschlußstück statt
Überstromblende
Y3
DV
Closing piece instead
of orifice
p ÖL
pV
pT
Öldruck
Ölpumpe
T
28.10.2002
Y4
S6
Y2
Service Department (ESS)
V
S7
po
zur Saugseite
Verdichter
MAX
MIN
20

21. LT-DUO–external oil pump

Grasso
LT-DUO–external oil pump
Geschäftsbereich
Kältetechnik
LARGE Duo-Pack (Externe Ölpumpe / external oil pump)
Markteinführung/
Launch:
~04 / 2000
28.10.2002
Service Department (ESS)
21

22. LT-DUO–external oil pump–new design

Grasso
Geschäftsbereich
Kältetechnik
LT-DUO–external oil pump–new design
LARGE-Duo-Pack-new design (Externe Ölpumpe / external oil pump)
POS 880: Solenoid valve
In oil return piping
Stop/Check valve DN80
with linear ball bearings
~11/ 2002:
•Ölversorgung Ausgleichkolben (Anschluss „D“) ist pumpenlos
•oil supply balance piston (port „D“) not with oil pump-pressure
28.10.2002
Service Department (ESS)
22

23. MC-DUO–Internal– P+I - old

Grasso
MC-DUO–Internal– P+I - old
Geschäftsbereich
Kältetechnik
Medium Duo-Pack
Interne Ölpumpe (alte Version)/ internal oil pump (old version)
Standard
Solenoid valve block
ID: 501 298 372
28.10.2002
Service Department (ESS)
23

24. MC-DUO–Internal–MD11

Grasso
MC-DUO–Internal–MD11
Geschäftsbereich
Kältetechnik
Ölstoppventil
MEDIUM - DUO-Pack
Old Version
Regulierventil
Injektionsöl
gekühltes Öl
Interne Ölpumpe /
Internal oil pump
Aggregat
Injektionsöl
Schaltschema
Oil management
MD11
D
Ölzuführung
Injektionsöl
Verdichter
C2
Ölzuführung
Funktionsöl
Funktionsöl
C1
internes ÖldruckRegulierventil
E
S
p
Magnetventilblock
28.10.2002
Messung Öldruck
auf Druckseite Ölpumpe
Service Department (ESS)
interne Ölpumpe, angeflanscht
24

25. MC-DUO–Internal–P+I - new

Grasso
MC-DUO–Internal–P+I - new
Geschäftsbereich
Kältetechnik
Medium Duo-Pack
Interne Ölpumpe (neue Version)/ internal oil pump (new version)
INTRODUCTION: 09 / 2001
PICT
TI
L
139,7x4
18x2
SP
EICT
SP
H
DN20/ 32-22barÜ
TSA
•Pos 110– new position
Öldrucksensor-oil pressure sensor
H
TSA
H
18x2
PIT
SP
GIBT
H
PSZA
H
TIA
PIAT
H
H
PSZA
H
PSZA
H
H
168,3x4,5
H
TSA
76,1x2,9
60,3x2,9
PIAT
33,7x2,6
PSZA
H
42,4x2,6
33,7x2,6
42,4x2,6
H
L
5)
TCB
33,7x2,6
H
L
5)
TIA
PIT
33,7x2,6
GIBT
•Pos 630
Absperrventil/ stop valve
•Pos 620
Rückschlagventil / check valve
H
EICT
DN20/ 32-22barÜ
33,7x2,6
•Magnetventilblock ohne Blende/
Solenoid valve block without orifice
114,3x3,6
12x1,5
139,7x4
76,1x2,9
12x1,5
12x1,5
12x1,5
12x1,5
PIT
•Pos 625 Öldruckregulierventil/
oil pressure regulating valve
TIA
H
26,9x2,3
TC
L
•Leitung E (& Rückschlagventil)
Piping E (& check valve)
28.10.2002
48,3x2,6
Service Department (ESS)
25

26. MC-DUO–Internal–MD11-R1

Grasso
MC-DUO–Internal–MD11-R1
Geschäftsbereich
Kältetechnik
Ölstoppventil
MEDIUM - DUO-Pack
NEW VERSION
Aggregat
Ölfilter
gekühltes Öl
Regulierventil
Injektionsöl
Interne Ölpumpe /
Internal oil pump
Ölzuführung
Injektionsöl
Injektionsöl
Messung Öldruck
Funktionsöl
pmin=pend-3,5 bar
D
Verdichter
Schaltschema
Oil management
p
C2
Ölzuführung
Funktionsöl
Funktionsöl
Verschlussstück
C1
Magnetventilblock
ohne Blende
MD11-R1
E
interne Ölpumpe, angeflanscht
S
externes Öldruck-Regulierventil
p=
4,5 bar
bei Betrieb
28.10.2002
Service Department (ESS)
vor Start, wenn ein Verdichter
bereits in Betrieb
26

27. MC-DUO–external–p+I -old

Grasso
MC-DUO–external–p+I -old
Geschäftsbereich
Kältetechnik
Medium Duo-Pack
Externe Ölpumpe (alte Version)/ external oil pump (old version)
Standard
Solenoid valve block
ID: 501 298 372
28.10.2002
Service Department (ESS)
27

28. MC-DUO–external–MD12

Grasso
MC-DUO–external–MD12
Geschäftsbereich
Kältetechnik
Ölfilter
MEDIUM - DUO-Pack
OLD VERSION
Externe Ölpumpe /
External oil pump
externes Öldruck-Regulierventil
(0,5...2,5 bar)
gekühltes Öl
Aggregat
Ölstoppventil
Regulierventil
Injektionsöl
Schaltschema
Oil management
externe Ölpumpe
Ölstoppventil
D
Injektionsöl
ÖLzuführung
Injektionsöl
Verdichter
C2
MD12
Ölzuführung
Funktionsöll
Funktionsöl
C1
E
S
p
Magnetventilblock
intern versorgt
28.10.2002
Messung Öldruck
auf Pumpendruckseite
Service Department (ESS)
28

29. MC-DUO–external–P+I - new

Grasso
MC-DUO–external–P+I - new
Geschäftsbereich
Kältetechnik
Medium Duo-Pack
Externe Ölpumpe (neue Version)/ external oil pump (new version)
INTRODUCTION: 09 / 2001
PICT
TI
L
114,3x3,6
12x1,5
139,7x4
139,7x4
•Magnetventilblock ohne Blende/
Solenoid valve block without orifice
18x2
SP
EICT
SP
H
EICT
DN20/ 32-22barÜ
H
DN20/ 32-22barÜ
TSA
H
TSA
H
•Pos 110– new position
Öldrucksensor-oil pressure sensor
18x2
PIT
GIBT
L
SP
TCB
TSA
H
TIA
H
PIAT
H
PSZA
H
PSZA
H
76,1x2,9
48,3x2,6
76,1x2,9
60,3x2,9
H
33,7x2,6
PSZA
168,3x4,5
H
33,7x2,6
H
42,4x2,6
48,3x2,6
PIAT
33,7x2,6
PSZA
H
H
L
42,4x2,6
TIA
33,7x2,6
33,7x2,6
H
33,7x2,6
•Pos 610
Absperrventil/ stop valve
GIBT
PIT
42,4x2,6
PIT
TIA
H
p=0,5 .. 2,0 bar
SP
26,9x2,3
TC
L
48,3x2,6
28.10.2002
Service Department (ESS)
29

30. MC-DUO–external–MD12-R1

Grasso
MC-DUO–external–MD12-R1
Geschäftsbereich
Kältetechnik
externes Öldruck-Regulierventil
Ölfilter
(0,5...2,0 bar)
MEDIUM - DUO-Pack
NEW VERSION
Externe Ölpumpe /
External oil pump
gekühltes Öl
Aggregat
Ölstoppventil
Ölstoppventil
Regulierventil
Injektionsöl
externe Ölpumpe
D
Injektionsöl
Schaltschema
Oil management
Messung Öldruck
auf Pumpendruckseite
p
ÖLzuführung
Injektionsöl
Verdichter
C2
Ölzuführung
Funktionsöll
Funktionsöl
C1
Verschlussstück
MD12-R1
E
S
Magnetventilblock ohne Blende
extern versorgt
28.10.2002
Service Department (ESS)
30

31. SH-DUO–internal–P+I -new

Grasso
SH-DUO–internal–P+I -new
Geschäftsbereich
Kältetechnik
SMALL DUO-Pack
Interne Ölpumpe (neue Version)/ internal oil pump (new version)
INTRODUCTION:
09 / 2001
DN 100
DN 65
DN9
G1/ 2"
R12x1,5
DN 25
DN 25
•Magnetventilblock
ohne Blende/
•Solenoid valve block
without orifice
•Pos 110– new position
Öldrucksensor
oil pressure sensor
•Pos 620/625
Check valve/
regulating valve
•Pos 630
stop valve
28.10.2002
DN9
G1/ 2"
R12x1,5
2
1
DN9
G1/ 2"
R12x1,5
DN
DN40
TC
L
3
DN9
G1/ 2"
R12x1,5
DN9
G1/ 2"
R12x1,5
DN
Service Department (ESS)
31

32. SH-DUO–internal–SD11-R1

Grasso
SH-DUO–internal–SD11-R1
Geschäftsbereich
Kältetechnik
SMALL - DUO-Pack
NEW VERSION
interne Ölpumpe /
internal oil pump
p measuring oil pressure functional oil
Pmin=pcon – 4,5 bar
H
X2
N
basic plate
oil management block 2
R
C
oil supply
cooled oil
to oil filtetr
from oil filter
solenoid stop valve
injected oil
Schaltschema
Oil management
Screw
compressor
functional oil
oil flow control valve
injected oil
closing stopper
Z
L
SD11-R1
internal oil pump, flanged housing
X1
solenoid valve block
external oil pressure relief valve
p = 4,5 bar
28.10.2002
Service Department (ESS)
before start if the second
compressor in operation
in operation
32

33. SH-SD11-R1-photo

Grasso
SH-SD11-R1-photo
Geschäftsbereich
Kältetechnik
SH-DUO-Pack-NEW VERSION
SD11-R1
N
Check
valve
Check
valve
Oil pressure relief
valve; 4,5 bar
X1
to X1
to N for measuring oil
pressure
L (from oil pump)
to oil pump
to connection H
28.10.2002
Service Department (ESS)
33

34. SH-DUO–external–P+I - new

Grasso
SH-DUO–external–P+I - new
Geschäftsbereich
Kältetechnik
SMALL Duo-Pack
Externe Ölpumpe (neue Version)/ external oil pump (new version)
DN 100
INTRODUCTION:
09 / 2001
DN 65
•MVBL ohne
Blende/
•Sol.valve block
without orifice
•Pos 110:
•new position
oil pressure sensor
2
TC
1
•Pos 610 / 615
stop valves
28.10.2002
R 2"
L (R60,3x2,9)
3
Service Department (ESS)
DN40
DN 50
R 2"
(R60,3x2,9)
DN 50
34

35. SH-DUO–external–SD12-R1

Grasso
SH-DUO–external–SD12-R1
Geschäftsbereich
Kältetechnik
Ölstoppventil
Externe Ölpumpe
Externes Öldruckregulierventil (0,5...2,0 bar)
SMALL - DUO-Pack
NEW VERSION
Externe Ölpumpe /
External oil pump
p
gekühltes Öl
Aggregat
Messung
Öldruck
Funktionsöl
p
Messung Öldruck
nach Filter
N
Externes Öfilter
X2 R
K
C
Öleintritt
Schaltschema
Oil management
Ölstoppventil
Injektionsöl
Regulierventil
Injektionsöl
Verdichter
Funktionsöl
Verschlußstück
L
SD12-R1
Ölmanagementblock 2
Grundplatte
X1
Verschlussstück
Magnetventilblock
ohne Blende
28.10.2002
Service Department (ESS)
35

36. LT-DUO- start control

Grasso
LT-DUO- start control
Geschäftsbereich
Kältetechnik
LARGE-Duo-Pack - ext. oilpump - start control
28.10.2002
Service Department (ESS)
36

37. LT-DUO-start control mod.

Grasso
LT-DUO-start control mod.
Geschäftsbereich
Kältetechnik
LARGE-Duo-Pack – external oil pump
modified start control
Einführung/
Introduction:
~09 / 2002
28.10.2002
Service Department (ESS)
37

38. DUO-internal oil pump-start control

Grasso
Geschäftsbereich
Kältetechnik
DUO-internal oil pump-start control
Duo-Pack – internal oil pump
start control
28.10.2002
Service Department (ESS)
38

39. Chillers – FX PP

Grasso
Chillers – FX PP
Geschäftsbereich
Kältetechnik
FKS /Chiller – FX PP
28.10.2002
Service Department (ESS)
39

40. Chillers – FX PP

Grasso
Chillers – FX PP
Geschäftsbereich
Kältetechnik
Hochdruckschwimmer /High pressure float
Entlüftungsventil
Venting valve
Unterdruckdüse
Low pressure nozzle
Eingangsventil
Inlet valve
Hebel – Betriebsstellung: unten
Level – operation position: downwards
Ausgangsventil
Outlet valve
Ablaßventil
Drain valve
28.10.2002
Service Department (ESS)
40

41. Chillers – FX VP

Grasso
Chillers – FX VP
Geschäftsbereich
Kältetechnik
FKS /Chiller – FX VP
28.10.2002
Service Department (ESS)
41

42. Chillers – FX VP

Grasso
Chillers – FX VP
Geschäftsbereich
Kältetechnik
Niveauregler /liquid level control - PMFL & SV
28.10.2002
Service Department (ESS)
42

43. Chiller – FX VP

Grasso
Chiller – FX VP
Geschäftsbereich
Kältetechnik
Niveauregler /liquid level control – RTK motor valve
28.10.2002
Service Department (ESS)
43

44. FX VP- Injector

Grasso
FX VP- Injector
Geschäftsbereich
Kältetechnik
Injector
from liquid separator
to evaporator
from liquid receiver
to drainer
28.10.2002
Service Department (ESS)
44

45. FX VP- drainer

Grasso
FX VP- drainer
Geschäftsbereich
Kältetechnik
Entöler / drainer
Hot gas
from injector
to suction
28.10.2002
Service Department (ESS)
45

46. Chiller DX RR

Grasso
Chiller DX RR
Geschäftsbereich
Kältetechnik
FKS /Chiller – DX RR
28.10.2002
Service Department (ESS)
46

47. Chiller DX LR

Grasso
Chiller DX LR
Geschäftsbereich
Kältetechnik
FKS /Chiller – DX LR
28.10.2002
Service Department (ESS)
47

48. Oil separator / MEDIUM & LARGE

Grasso
Oil separator / MEDIUM & LARGE
Geschäftsbereich
Kältetechnik
Ölabscheider / oil separator: Ø508, Ø711, Ø813
II
XI
XX
III
XVI
IX
VI
XIX
XII
I
V
XIV
XVIII
IV
XIII
XVII
VIII
XV
X
I
Kältemitteleintritt
Refrigerant inlet
II
Kältemittelaustritt
Refrigerant outlet
III
Überströmventil/ Sicherheitsventil
Overflow valve/ Safety valve
IV
Ölaustritt zum Ölkühler
Oil outlet to oil cooler
V
Gasschwingungsschutz
Gas pulsation protection
VI
Ölrückführung
Oil return
VII
Ölablaß
Oil drain
VIII
Ölheizung
Oil heater
IX
Schauglas – Ölfeinabscheidestufe
Sight glass – oil fine separation stage
X
Schauglas – Ölniveau Ölsammler
Sight glass – oil level in oil receiver
XI
Meßleitung/ Umgehungsleitung
Measuring line/ bypass line
XII
Drucktransmitter Enddruck
Pressure transm. /discharge pressure
XIII
Niveauwächter MIN.I
Level controller MIN.I
XIV
Niveauwächter MAX.I
Level controller MAX.I
XV
Öltemperatur – Ölsammler
Oil temperature – oil receiver
XVI
Sicherheitsdruckbegrenzer
Safety pressure limiter
XVII
Niveauwächter MIN.II
Level controller MIN.II
XVIII
Niveauwächter MAX.II
Level controller MAX.II
XIX
Agglomerator
Agglomerator
XX
Feinabscheidepatronen
Fine separation cartridges
VII
28.10.2002
Service Department (ESS)
48

49. Oil separator / LARGE

Grasso
Oil separator / LARGE
Geschäftsbereich
Kältetechnik
Ölabscheider / oil separator: Ø1016, Ø1200, Ø1400
I
Kältemitteleintritt
Refrigerant inlet
II
Kältemittelaustritt
Refrigerant outlet
III
Überströmventil/ Sicherheitsventil
Overflow valve/ Safety valve
IV
Ölaustritt zum Ölkühler
Oil outlet to oil cooler
V
Gasschwingungsschutz
Gas pulsation protection
VI
Ölrückführung
Oil return
VII
Ölablaß
Oil drain
VIII
Ölheizung
Oil heater
IX
Schauglas - Ölfeinabscheidestufe
Sight glass – fine separation stage
X
Schauglas – Ölniveau Ölsammler
Sight glass – oil level in oil receiver
XI
Meßleitung/ Umgehungsleitung
Measuring line/ bypass line
XII
Drucktransmitter Enddruck
Pressure transm./disch. pressure
XIII
Niveauwächter MIN.I
Level controller MIN.I
XIV
Niveauwächter MAX.I
Level controller MAX.I
XV
Öltemperatur - Ölsammler
Oil temperature – oil receiver
XVI
Sicherheitsdruckbegrenzer
Safety pressure limiter
XVII
Niveauwächter MIN.II
Level controller MIN.II
XVIII
Niveauwächter MAX.II
Level controller MAX.II
XIX
Agglomerator
Agglomerator
XX
Feinabscheidepatronen
Fine separation cartridges
XXI
Endtemperatur
Discharge temperature
II
XI
XX
XVI
III
IX
VI
XXI
V
XII
XIX
XIV
I
XVIII
XIII
X
IV
XVII
X
X
VII
28.10.2002
VIII
XV
Service Department (ESS)
49

50. Oil separator / LARGE

Grasso
Oil separator / LARGE
Geschäftsbereich
Kältetechnik
Ölabscheider / oil separator: Ø1600, Ø1800, Ø2000, Ø2200
XXII
XI
II
XXIII
III
XVI
VI
IX
V
XXI
XII
XIX
VIII
IV
XXIV
XVII
VII
28.10.2002
Refrigerant inlet
II
Kältemittelaustritt
Refrigerant outlet
III
Überströmventil/ Sicherheitsventil
Overflow valve/ Safety valve
IV
Ölaustritt zum Ölkühler
Oil outlet to oil cooler
V
Gasschwingungsschutz
Gas pulsation protection
VI
Ölrückführung
Oil return
VII
Ölablaß
Oil drain
VIII
Ölheizung
Oil heater
IX
Schauglas - Ölfeinabscheidestufe
Sight glass–fine separation stage
X
Schauglas - Ölsammler
Sight glass – oil receiver
XI
Meßleitung/ Umgehungsleitung
Measuring line/ bypass line
XII
Drucktransmitter Enddruck
Pressure transm./disch.pressure
XIII
Niveauwächter MIN.I
Level controller MIN.I
XIV
Anschluß Niveauwächter MAX.I
Connection, level controller MAX.I
XV
Öltemperatur - Ölsammler
Oil temperature – oil receiver
XVI
Sicherheitsdruckbegrenzer
Safety pressure limiter
XVII
Niveauwächter MIN.II
Level controller MIN.II
XVIII
Niveauwächter MAX.II
Level controller MAX.II
XIX
Agglomerator
Agglomerator
XX
Feinabscheidepatronen
Fine separation cartridges
XXI
Endtemperatur
Discharge temperature
XXII
Deckel (Austausch Abscheidepatr.)
Cover(replacement of cartridges)
XVIII
X
X
XX
Kältemitteleintritt
XII
XIII
XXI
X
I
XV
Service Department (ESS)
50

51. Oil separator SMALL

Grasso
Oil separator SMALL
Geschäftsbereich
Kältetechnik
Ölabscheider / oil separator: SMALL
Item Designation
1
refrigerant inlet
2
refrigerant outlet
3
4
5
28.10.2002
Bezeichnung
Kältemitteleintritt
Kältemittelaustritt
agglomerator/ demister Agglomerator
(not shown in fig.1)
oil fine separation
Ölfeinabscheidepatrone
cartridge
cover
Deckel
Item Designation
6
oil level indicator
7
level switch connection
8
oil heater connection
Bezeichnung
Ölniveanzeige
Ölniveauschalteranschluß
Ölheizungsanschluß
9
oil outlet to oil cooler
Ölaustritt zum Kühler
10
main oil return from oil
fine separation section
Ölrückführung von
Feinabscheideteil
Service Department (ESS)
51

52. Level switches

Grasso
Level switches
Geschäftsbereich
Kältetechnik
Niveauanzeiger - optoelektronisch / level switches - optoelectronical
Sight glas adapter
sensor
Connection diagram
Pin assignment
28.10.2002
Service Department (ESS)
52

53. Oil cooler: HS COOLER

Grasso
Oil cooler: HS COOLER
Geschäftsbereich
Kältetechnik
Ölkühler wassergekühlt / oil cooler water cooled
Two Pass
Tubeside (KS20):
One Pass
Tubeside (KS20):
28.10.2002
Service Department (ESS)
53

54. Oil cooler: HS COOLER

Grasso
Oil cooler: HS COOLER
Geschäftsbereich
Kältetechnik
Baureihenkennzeichnung / Designation code
KS1 2 - AEP- 8 2 2
L 1000
LÄNGE ZWISCHEN ROHRPLATTEN / DISTANCE BETWEEN TUBEPLATES L [mm] [400-3600]
OPTION: BESCHICHTUNG / COATING
OPTION: TURBULATOREN / TURBULATORS
ZAHL DER UMLENKUNGEN / NUMBER OF BAFFLES (0/1/2/3/4)
EIN- ZWEI FLUTIG / PATH TUBESIDE (1/2)
RIPPENTEILUNG / FIN PITCH LT [mm] (ONLY LAST FIGURE: 0.8 / 1.1 / 1.4)
RUNDRINGE / MATERIAL OF O-RING / SEALING STRIPS (NBR / HNBR / VITON / NEOPRENE / EPDM)
ROHRMATERIAL / MATERIAL OF TUBES (CUNI / STAINLESS STEEL / TITANIUM)
DECKELMATERIAL / MATERIAL OF WATERBOX (BRONZE / ALUMINIUM / STEEL FOR REFRIGERANTS, NH3)
GEHÄUSEDURCHMESSER / SHELL DIAMETER (ONLY THE FIRST TWO FIGURES: DN 125 / DN 200 / DN 250)
GEHÄUSEMATERIAL / SHELL
(ALUMINIUM)
DESIGN (STEEL)
BAUREIHE / COOLER SERIES K
28.10.2002
Service Department (ESS)
54

55. Oil cooler: HS COOLER

Grasso
Oil cooler: HS COOLER
Geschäftsbereich
Kältetechnik
Leistungsdaten / performance data
KS 12
L=400
L=800
L=1200
L=1600
L=2000
L=2600
L=3200
L=3600
exchange area A

6,80
13,76
20,64
27,52
34,40
47,20
55,04
61,92
volume oil side
l
3,1
5,8
8,4
11,0
13,7
17,6
21,5
24,2
volume water side
l
2,5
3,7
4,8
6,0
7,1
8,8
10,5
11,4
kW
37
85
120
52
65
85
125
145
Oil cooling capacity
1) NH3
Heat recovery capacity 2) NH3
kW
m3/h
Water volume flow
KS 20
4,6
9,2
9,5
3,1
3,4
5,0
7,3
8,5
L=400
L=800
L=1200
L=1600
L=2000
L=2600
L=3200
L=3600
exchange area A

21,17
33,88
50,82
67,76
84,70
110,11
135,52
152,46
volume oil side
l
9,4
14,3
20,9
27,5
34,1
44,0
53,9
60,5
volume water side
l
8,5
10,7
13,5
16,3
19,2
23,4
27,7
29,3
kW
145
195
290
135
160
225
320
375
7,9
8,25
13,2
18,7
21,9
Oil cooling capacity
1) NH3
Heat recovery capacity 2) NH3
Water volume flow
kW
m3/h
25,0
17
25
1)
2)
28.10.2002
Oil inlet=80°C / Oil outlet=50°C / water inlet= <30°C
Oil inlet=80°C / Oil outlet=55°C / water inlet= 45°C
Service Department (ESS)
55

56. Oil cooler: AEL

Grasso
Oil cooler: AEL
Geschäftsbereich
Kältetechnik
Ölkühler wassergekühlt / oil cooler water cooled
Oil
Water
Korrosives Wasser - Rippenrohre
Corrosive water – finned tubes
Oil
Typ / Type
Austauschfläche / Exchange area
Ölkühlungsleistung / Oil cooling capacity NH3 (2)
Ölkühlungsleistung / Oil cooling capacity NH3 (1)
max. zul. Wasserdurchsatz / max. water flow
Durchmesser / Diameter
Gesamtlänge / Length
Rohrbündellänge / Tube length
Öl Ein- und Austritt / Size oil in- and outlet
Wasser Ein- und Austritt / Size water in- and outlet
Masse / Weight

kW
kW
m³/ h
mm
mm
mm
DN
DN
kg
H / 1400 H / 2300 L / 2300 J / 1400 M / 2300
3,8
6,4
10,7
13,9
23,4
60
70
105
180
250
35
60
100
140
240
6,0
6,0
10,0
20,0
20,0
125
125
150
200
200
1525
2425
2413
1542
2442
1400
2300
2300
1400
2300
40
40
40
50
50
32
32
32
50
50
61
80
108
143
210
Auslegungsdaten / Data for capacity calculation
Wasser-Eintritt / Water inlet temperature
28.10.2002
< 30°C
Service Department (ESS)
56

57. Oil cooler: AEL

Grasso
Oil cooler: AEL
Geschäftsbereich
Kältetechnik
Ölkühler kältemittelgekühlt / oil cooler refrigerant cooled
Kältemittelaustritt
Refrigerant
Öleintritt
Oil
Glattrohr mit Turbulenzstreifen /
Plain tubes with turbulence stripes
Ölaustritt
Oil
Refrigerant
Kältemitteleintritt
Typ / Type
Fläche / Exchange area
1501000
2001500
2002000
2502000
3001500
3501500
3502000
4002000
4502000
5002000
5502000
5502500
1,1
3,9
5,2
9,9
11,3
14,8
19,7
25,3
34
44,6
54,7
68,4

Ölkühlleistung / Oil cooling capacity
Ölkühlleistung / Oil cooling capacity
2) kW
1) KW
Durchmesser / Diameter
d
mm
Länge / Total length
l
Rohrlänge / Tube length
10
35
70
115
160
215
270
350
500
600
750
-
150
10
200
35
200
70
250
80
300
100
350
115
350
215
400
300
450
400
500
500
550
650
550
mm 1200
1700
2200
2200
1700
1700
2200
2200
2200
2350
2362
2862
l1 mm 1000
1500
2000
2000
1500
1500
2000
2000
2000
2000
2000
2500
NW Öl / Oil connection
DN
32
40
40
40
50
50
50
50
65
80
100
100
NW Kältemittel ein / Refrigerant inlet
DN
32
40
50
50
65
65
65
80
100
100
100
100
NW Kältemittel aus Refrigerant outlet
DN
40
50
65
65
65
80
80
100
125
125
150
150
Charge refrigerant
l
13
34
45
67
67
80
106
132
167
205
235
295
Charge oil
l
4
13
18
32
38
50
64
86
103
152
170
220
Technical specifications / Technische Spezifikation:
28.10.2002
2)
Condensing temperature/
max. +40°C
oil inlet / Öleintritt
90°C
oil outlet / Ölaustritt
60°C
1)
Condensing temperature/
max. +40°C
oil inlet / Öleintritt
80°C
oil outlet / Ölaustritt
50°C
Service Department (ESS)
57

58. Suction filter

Grasso
Suction filter
Geschäftsbereich
Kältetechnik
Saugfilter / Suction filter
1
8
6
Item
NB 150/ 200/ 250
NB 300/ 350
2
3
4
5
10
9
7
NB 250
28.10.2002
Designation
Bezeichnung
1
Housing
2
Cover
3
Filter element
4
O ring
5
O ring (for position 3)
6
Refrigerant inlet
Kältemitteleintritt
7
Refrigerant outlet
Kältemittelaustritt
8
Venting port
9
Port for PT100/ PT1000
10
Port for pressure
measuring
Service Department (ESS)
Gehäuse
Deckel
Filter
Rundring
Rundring (für Pos. 3)
Entlüftung
Anschluß PT100/ PT1000
Drucksensoranschluß
58

59. Steel lamination coupling

Grasso
Steel lamination coupling
Geschäftsbereich
Kältetechnik
Kupplung / Steel lamination coupling
Compressor side
Motor side
Pos. – Nr. / Pos.-No.
1
2
3
4
5
6
7
8
9
28.10.2002
Description
Motorseit ige Nabe
Motorseit iger Spannring
Verdichterseit ige Nabe
Verdichterseit iger Spannring
Zwischenstück
Lammellenpakete
Spannsatzschrauben (Motorseit e)
Spannsatzschrauben (Verdichterseite)
Paßschraube
Service Department (ESS)
Bezeichnung
Drive side hub
Drive side clamping ring
Compressor side hub
Compressor side clamping ring
Spacer
Disc packs
Tapered bush screws (drive side)
Tapered bush screws (Motor side)
Fit bolts
59

60. Steel lamination coupling

Grasso
Steel lamination coupling
Geschäftsbereich
Kältetechnik
Kupplung /
Steel lamination coupling
Anzugsmoment für
Spannverbände:
Tightening torques for
tensioning set:
Anzugsmoment für
Lamellenpakete:
Tightening torques for
lamination package:
Anzugsmomente für Spannsatzschrauben / Tightening torque for tapered bush screws
Verdichterseite / Compressor side
Motorseite / Drive side
Kupplungsgröße Wellendurchmesser
Gewinde
Tan
Wellendurchmesser
Gewinde
[Nm]
Coupling Size
Shaft diameter
Screw Size
Shaft diameter
Screw Size
66 E60
40
M8
30
55
M6
E70
50
M6
14
65
M8
105 E70
50
M10
59
55
M8
60
M8
20
60
M6
65
M6
70
M8
168 E70
60
M8
25
75
M6
260 E80
60
M8
30
65
M6
80
M8
30
70
M8
75
M6
80
M8
330 E105
80
M12
59
80
M10
85
M8
90
M8
95
M6
100
M6
330 E120
520 E120
660 E120
Tan
[Nm]
12
20
30
12
12
30
14
12
30
14
30
59
30
30
12
12
Anzugsmomente für Paßschrauben / Tightening torque for fitbolts
Kupplungsgröße Paßschraubengröße
Tan
Tan
Ausbaumaß [mm]
Coupling Size
Fitbolts size
[Nm]
[Nm]
Coupling distance [mm]
NEW values*
66
M 10x35
67
66
60/ 70 + 0,20
105
M 12x40
115
115
70 + 0,20
168
M 16x46
290
250
70 + 0,20
260
M 16x48
290
250
80 + 0,25
330
M 20x65
560
490
105/ 120 + 0,25
520
M 20x65
490
120
660
M 24x70
840
120
*NEW values: since 04/2003
28.10.2002
Service Department (ESS)
60

61. Steel lamination coupling

Grasso
Steel lamination coupling
Geschäftsbereich
Kältetechnik
Kupplung / Steel lamination coupling
top
0
0
Radial misalignment
left
right
Versatz
bottom
top
0
0
Angular misalignme nt
left
right
Klaffung
bottom
28.10.2002
Service Department (ESS)
61

62. Coupling SMALL

Grasso
Coupling SMALL
Geschäftsbereich
Kältetechnik
Kupplung / coupling SMALL
design T:
design K:
Abbau des Kupplungsschutzes (2.2) am Kupplungsgehäuse. Ölrohr (5.4) aus dem Deckel der Gleitringdichtung herausdrehen. Sechskantschrauben (2.7)aus
motor- und verdichterseitiger Kupplungsnabe herausschrauben. Kupplungsmittelteil (2.5) zusammendrücken, so d aß die Zentrieransätze aus den Naben
rutschen. Kupplungsmittelteil mit dazwischenliegendem elastischen Zwischenring (2.4) herausnehmen. Zylinderschrauben (2.6) des Spannverbandes der
verdichterseitigen Kupplungsnabe lösen und Nabe von der Verdichterwelle ziehen.
Remove the coupling guard (2.2) on the coupling housing. Twist out the oil pipe (5.4) from the cover of the mechanical contact seal.
Unscrew the hex. screws (2.7) from the coupling hub on motor and compressor side. Press the central part of the coupling (2.5) so that the centering shoulders
slide out of the hubs. Remove the central part of the coupling together with the elastic spacer ring (2.4) located in between. Unscrew the cheese-headed
screws (2.6) of the clamping joint of the coupling hub on the compressor side and pull off the hub from the compressor shaft.
28.10.2002
Service Department (ESS)
62

63. Option –oil filter P+I

Grasso
Option –oil filter P+I
Geschäftsbereich
Kältetechnik
Doppelölfilter / Double oil filter
Grobfilter / coarse filter
for NEW refrigerants:
coarse filter (e.g. 40µm)
fine filter (e.g. 25µm)
28.10.2002
Service Department (ESS)
63

64. Option – double oil filter

Grasso
Option – double oil filter
Geschäftsbereich
Kältetechnik
Doppelschaltfilter / double oil filter
28.10.2002
Service Department (ESS)
64

65. Temperature sensor

Grasso
Temperature sensor
Geschäftsbereich
Kältetechnik
Temperatursensor / temperature sensor
Protection tube /
Schutzrohr :
Durchmesser/diameter:
8 mm;
Edelstahl / high grade
steel;
Verschraubungslänge /
30 / 60 / 90 / 120 mm
Fitting length :
Fühlerdurchmesser /
4 - 5 mm
Measuring compartment :
Gewindeanschluß /
M12x1,5
Screw-in-thread :
Schutzgrad /
IP 54
Degree of protection:
28.10.2002
Betriebsdruck (max.)
Pressure range :
Max. 35 bar
Temperature range :
-50°C to 140°C
Service Department (ESS)
65

66. Fine filter cartridges

Grasso
Fine filter cartridges
Geschäftsbereich
Kältetechnik
Feinabscheidepatrone / Fine filter cartridges
REPLACEMENT OF THE OIL SEPARATION
CARTRIDGES
1. Close the discharge and suction side shutoff fittings.
2. Draw off refrigerant and depressurize the
SCP.
3. Check the pressure on the display of the
compressor control device or connect a test
pressure gauge.
4. Remove the pipe bend from the oil
separator.
5. Remove the non-return valve built in the
oil separator. This step is omitted if a nonreturn valve is used the discharge side of
which can be shut off.
6. Remove the locking wire [3].
7. Loosen the hexagon head screws [2] used
to attach the oil fine separation cartridges.
8. Remove the cartridge [1].
9. Mount the new cartridge in the reverse
sequence.
28.10.2002
Service Department (ESS)
AUSTAUSCH DER
FEINABSCHEIDEPATRONEN
1. Schließen der Absperrventile auf der Saugund Druckseite.
2. Entfernen des Kältemittels und Ablassen
des Drucks.
3. Kontrolle des Aggregatedrucks.
4. Demontage des Rohrbogens am Austritt
Ölabscheider.
5. Demontage des im Ölabscheider
eingebauten Rückschlagventils. Bei
externem Rückschlagventil ist dies nicht
notwendig.
6. Entfernen des Sicherungsbandes [3].
7. Lösen der Muttern auf der Oberseite der
Patrone [2].
8. Ausbau der Feinabscheidepatronen.
9. Montage in der entgegengesetzten
Reihenfolge.
66

67. Oil heater

Grasso
Oil heater
Geschäftsbereich
Kältetechnik
Ölheizung / oil heater
60°C
28.10.2002
150°C
Service Department (ESS)
67

68. Oil heater I

Grasso
Oil heater I
Geschäftsbereich
Kältetechnik
Ölheizung / oil heater
60°C
150°C
Reset
28.10.2002
Service Department (ESS)
68

69. Oil heater II

Grasso
Oil heater II
Geschäftsbereich
Kältetechnik
Ölheizung / oil heater - HELIOS
60°C
150°C
Reset
28.10.2002
Service Department (ESS)
69

70. Motorbefestigung - fixator

Grasso
Motorbefestigung - fixator
Geschäftsbereich
Kältetechnik
Motorfixatoren - Fixator
Fixierung Motorfuß Linksgewinde
Fixation motorAnti-clockwise threaded
Höheneinstellung Motorfuß Rechtsgewinde
Height adjustment motorclockwise threaded
28.10.2002
Service Department (ESS)
70

71. Multifunctional block I

Grasso
Multifunctional block I
Geschäftsbereich
Kältetechnik
Ölmanagementblock/Multifunctional block
28.10.2002
Service Department (ESS)
71

72. Multifunctional block II

Grasso
Multifunctional block II
Geschäftsbereich
Kältetechnik
Ölmanagementblock/Multifunctional block
28.10.2002
Service Department (ESS)
72

73. Multifunctional block III

Grasso
Multifunctional block III
Geschäftsbereich
Kältetechnik
MEDIUM - Ölmanagementblock/Multifunctional block
from
fromoil
oil
separator
sep arator
vom
Ölab scheid er
Ölfiltergehäuse
Oil filter housing
Ölverteiler
Oil distributor
oil filter housing
oil distributor
vom
Ölkühler
fromfrom
oil
oil cooler
cooler
28.10.2002
Service Department (ESS)
73

74. Multifunctional block IV

Grasso
Multifunctional block IV
Geschäftsbereich
Kältetechnik
MEDIUM - Ölmanagementblock/Multifunctional block
VII VI
XV
IV
III
TIZA
II
TC
I
XI
28.10.2002
Service Department (ESS)
74

75. Multifunctional block V

Grasso
Multifunctional block V
Geschäftsbereich
Kältetechnik
LARGE - Ölmanagementblock/Multifunctional block
28.10.2002
Service Department (ESS)
75

76. Multifunctional block VI

Grasso
Multifunctional block VI
Geschäftsbereich
Kältetechnik
LARGE - Ölmanagementblock/Multifunctional block
28.10.2002
Service Department (ESS)
76

77. Multifunctional block VII

Grasso
Multifunctional block VII
Geschäftsbereich
Kältetechnik
LARGE - Ölmanagementblock/Multifunctional block
28.10.2002
Service Department (ESS)
77

78. 3-way valve

Grasso
3-way valve
Geschäftsbereich
Kältetechnik
3-Wege-Ventil / 3-way-valve
start condition
cold oil
28.10.2002
operation condition
correct oil temperature
Service Department (ESS)
Increased
oil temperature
78

79. Oil pressure regulating valve

Grasso
Oil pressure regulating valve
Geschäftsbereich
Kältetechnik
Öldruckregulierventil / oil pressure regulating valve
Valve piston
(Old design)
Valve piston
(NEW design)
Since ~10/2002
POS 5: O-Ring 50x3
Valve piston seat
28.10.2002
Service Department (ESS)
79

80. Oil pump

Grasso
Oil pump
Geschäftsbereich
Kältetechnik
Ölpumpe / oil pump
NEW design:
hole for lifting screw
28.10.2002
Service Department (ESS)
80

81. Oil pump II

Grasso
Oil pump II
Geschäftsbereich
Kältetechnik
Ölpumpe / oil pump
Pressure balance:
shaft seal chamber to suction side
Operation range:
Suction pressure: < 16bara
Discharge pressure: < 25bara
28.10.2002
Service Department (ESS)
81

82. Pressure sensor

Grasso
Pressure sensor
Geschäftsbereich
Kältetechnik
Drucksensor / Pressure sensor
Versorgungsspannung:
Voltage:
Standardsignal:
Signal:
Betriebsdruck:
Max. pressure:
Schutzgrad:
Prot. Level:
Gewinde
Screw thread:
10 – 30 V Gleichstrom
10 –30 V DC
4 – 20 mA
35 bar
35 bar
IP 65
G ¼“
+Us
1
3
2
_
Standard pressure range:
•0-21bara (since 05/2003: 0-25 bara)
•0-7bara (for suction pressure)
28.10.2002
Service Department (ESS)
82
English     Русский Rules