Similar presentations:
Lecture 7 пдк
1. Lecture 7. Timber and Plywood Beams
Prepared by: Niyetbay S.E.2. Lecture objectives
– The purpose of this lecture is to explain:– the main types of timber and plywood beams;
– their structural features and applications;
– the behaviour of beams under load;
– the basic principles of strength, stiffness, and stability
calculations;
– the construction requirements for glued, reinforced, and
plywood-web beams.
3. General information about timber beams
– A beam is a structural member that carries transverse loads and transfers them tocolumns, walls, or other supports. Under loading, a beam mainly works in bending.
– Timber beams can be divided into two main groups:
– Solid-section beams.
– Built-up beams.
– Solid-section beams are made from a single piece of timber. They are commonly
used in floor structures, attic floors, and roof systems. Their span usually does not
exceed 6 m because the length and dimensions of solid timber are limited.
– Built-up beams consist of several separate elements connected to work together.
These elements may include boards, timber members, plywood sheets, glued
laminations, steel bars, or fibre-reinforced polymer bars.
4. General information about timber beams
– Built-up beams have several important advantages:– they can cover longer spans;
– small timber elements can be used;
– the cross-sectional shape can be selected according to the load;
– high-quality timber can be used only in highly stressed zones;
– the beams can be manufactured under factory conditions;
– their self-weight is relatively low;
– they allow efficient use of timber materials.
– Depending on the connection method, built-up beams may be glued,
nailed, bolted, or reinforced.
– Glued beams usually have greater stiffness than mechanically
connected beams. In a glued beam, the individual laminations work
almost as one continuous structural member. In nailed or bolted beams,
small slips may develop between the individual elements, reducing the
overall stiffness.
5. Classification of timber beams
– Timber beams may be classified according to theirmaterial and structural form.
– The main types are:
– glued laminated timber beams;
– curved glued laminated beams;
– pitched or tapered glued beams;
– reinforced timber beams;
– beams made from different timber species;
– flat plywood-web beams;
– corrugated plywood-web beams;
– built-up solid-timber beams.
– The beam type is selected according to:
– the required span;
– the magnitude and type of loading;
– the shape of the roof;
– the required structural depth;
– the environmental conditions;
– architectural requirements;
– manufacturing possibilities.
6. Classification of timber beams
– Typical recommended spans areapproximately:
– glued laminated timber beams: 12–24 m;
– curved glued beams: 12–30 m;
– flat plywood-web beams: 6–18 m;
– corrugated plywood-web beams: 6–12 m;
– reinforced timber beams: 6–24 m;
– built-up solid-timber beams: 4–9 m.
– These values are approximate. The final
dimensions must always be determined
by structural calculation.
7. Figure 1. Main types of timber and plywood beams
– Figure description: The figure presentsbeams with constant and variable
depths, curved glued beams, flat
plywood-web beams, corrugated
plywood-web beams, reinforced
beams, and built-up solid-timber
beams. It shows how the beam
geometry changes depending on the
span and structural purpose.
8. Glued laminated timber beams
– Glued laminated timber beams are produced by bondingplaned timber boards with water-resistant structural
adhesive. The grain of the boards is normally oriented along
the longitudinal axis of the beam.
– The beam may have:
– a rectangular shape;
– a constant depth;
– a tapered depth;
– a single-pitched top surface;
– a double-pitched top surface;
– a curved central part.
– The main advantage of glued laminated timber is that the
material can be arranged according to the stress distribution.
9. Glued laminated timber beams
– Under bending, the highest normal stresses occur near the upper and lower edges of the cross-section. For thisreason, higher-grade timber is placed in the outer zones. Lower-grade timber may be used near the neutral
axis, where the bending stresses are smaller.
– For relatively slender beams, the high-quality outer zones should have a depth of at least approximately
\(0.15h\), where \(h\) is the total beam depth. Each outer zone should normally contain at least two boards.
– The approximate beam depth may initially be selected using:
–
ℎ
1
1
= 10 … 17
Construction